Short and long addresses
With bit 5 off, the decoder uses CV1. With bit 5 on, it uses CV17 and CV18. Program all required values; changing the address CVs alone may not switch the active address.
Calculate CV17 and CV18 →INTERACTIVE DCC TOOL
Build a value from clear choices, or decode the number already stored in your locomotive. DecoderHub preserves high bits instead of silently throwing them away.
BUILD A VALUE
DECODE A VALUE
These values are examples, not universal recommendations. Support still depends on the decoder.
With bit 5 off, the decoder uses CV1. With bit 5 on, it uses CV17 and CV18. Program all required values; changing the address CVs alone may not switch the active address.
Calculate CV17 and CV18 →Bit 2 requests power-source conversion. Some decoders do not support it, and analogue behaviour varies. HM7000 guidance specifically cautions against unsuitable analogue controllers in Bluetooth mode.
Bit 1 selects the modern function instruction used with 28/128 speed steps. A mismatch can make lights behave incorrectly even when the locomotive moves.
Bit 3 enables bidirectional communication where decoder, command station and layout hardware support it. Enabling the bit cannot add unsupported hardware.
Bits 6 and 7 need special care. The current NMRA material reserves bit 6 and uses bit 7 to distinguish accessory decoders. Do not clear either bit on an unknown device without its manual.
Reviewed 30 October 2026. Decoder instructions and current firmware notes take priority.